(Synchron-S, Мarch 2023)
SYNCHRON-S presents its new product - the fire protection system for server and electrical cabinets FRP-2A (Fire Rack Protection). SYNCHRON-C is the developer, manufacturer and installer of the new system.

Published in News

The FRP-2A (Fire Rack Protection) system is used for local monitoring as an early warning of fire danger or serious damage of electronic equipment, associated with the release of smoke and/or increase of temperature inside rack structures in data centers, server rooms, electrical cabinets and other similar facilities.

The FRP-2A system prevents the occurrence of fire and ensures almost 100% continuity of the work process, ensuring continuity of service to data center customers.

The FRP-2A system has been developed for early smoke detection and temperature control in any server cabinet. The goal is that when an incident occurs - release of smoke and/or heat, the system will register these events and identify in exactly which cabinet the problem has occurred.

In this way, timely action can be taken and a potential fire in the cabinet can be prevented. The speed of detection is extremely fast - from 8 to 20 seconds, despite strong ventilation and air exchange in the cabinet.


FRP-2A is the world’s first fire protection system for
each individual server cabinet.


Unique characteristics:

  • Continuous monitoring of smoke and heat by analyzing the outgoing air flow in each server cabinet.
  • Accurate location of a possible fire in each individual server cabinet.
  • Warning of fire occurrence in the server cabinet, as well as its spread to adjacent cabinets and cable routes.
  • Preventive temperature control function - programmable threshold for an alarm status for each individual server cabinet.
  • Alarming, control and statistics software for each server cabinet as well as the ability to adapt and upgrade according to user applications operating in a cloud/ virtual environment.
  • Saving up to 20% on cooling power when configuring each server cabinet based on the temperature statistics measured in the cabinet - a real-time temperature map.
  • Activation of light and sound alarm to alert personnel and take action in the event of an incident.
  • Verification and confirmation of Alarm/Failure status by the personnel on-site at the server cabinet.
  • System failure control - supply voltage, suction system, smoke and heat analysis sensors, all cables and connections to the device.

SYNCHRON-S is the developer, manufacturer and installer of the FRP-2A system.

 

Download FRP-2A brochure

 

Published in Products

The centers for storage and processing of data are essential components of today's communications infrastructure. The fire occurrence in the data centers can lead to catastrophic losses due to interruption of workflow or equipment failure.

Published in News